FCAW · Low-alloy steel

E81T1-Ni1

An 80 ksi gas shielded flux cored wire with a nickel addition, used where the finished joint must hold impact toughness at low service temperature.

What the designation means

E
Electrode carrying the welding current.
8
80,000 psi minimum tensile strength of the deposited weld metal.
1
All position capability.
T1
A tubular flux cored wire of usability class 1, a gas shielded rutile flux run on direct current electrode positive.
-Ni1
A nickel-bearing deposit at roughly one percent nickel, added to raise low temperature notch toughness.

At a glance

ProcessFCAW
FamilyLow-alloy steel
PositionsAll positions
PolarityDCEP
ShieldingA 75 to 80 percent argon blend with the balance carbon dioxide, or 100 percent carbon dioxide depending on the shielding designator on the label
Minimum tensile strength80 ksi

Typical uses

  • Bridge and offshore structures requiring low temperature toughness
  • High strength low alloy steel fabrication at the 80 ksi level
  • Heavy equipment fabrication under fatigue and impact loading

How it runs

  • Smooth spray-like transfer with a fast freezing slag for out of position work
  • Nickel addition raises impact toughness in cold service
  • Heat input must be controlled to protect the specified impact values
  • Full slag coverage and a clean, well washed bead face

Storage and handling

Alloy flux cored wire is moisture sensitive. Keep spools in sealed foil packaging with desiccant and rebag or oven store opened spools.

Compare with